Automation and innovation at the touch of a button


The GEM Premier 4000 system measures pH, blood gases, electrolytes, metabolites, CO-Oximetry and more, while automating quality management through iQM, instrument maintenance with its multi-use disposable GEM PAK and information management with GEMweb Plus 500 Custom Connectivity.

HIGHLIGHTS
  • Continuous quality assurance, everywhere
    iQM technology provides automated quality assurance, continuously, unlike traditional (auto or manual) QC offerings. With automatic detection, iQM performs continuous checks with each and every sample. Error detection time is reduced from hours to minutes and errors are automatically corrected and documented for a complete picture of quality.
  • Advanced simplicity
    Multi-use, GEM PAK offers advanced simplicity at every point-of-care. Fully self contained, the GEM PAK automates the most labor-and skill-intensive processes and is available in multiple menu and test volume configurations, GEM PAKs have a use-life of 31-days and require no refrigeration. They allow ultimate flexibility for point-of-care testing needs throughout the hospital.
  • Management and compliance simplified
    GEMweb Plus 500 Custom Connectivity is designed to simplify operator supervision and quality management with full traceability. All from a single interface, whether accessed in the lab, at the point-of-care or remotely from an analyzer, PC or tablet device, GEMweb Plus 500 provides customizable and automated functionality for complete control of analyzers and operators.

Self-contained, closed system for automated continuous assurance, regardless of operator or location.

GEM PAK, GEM Premier 4000 with iQM

Closed analytical system means outside variables are eliminated and errors are known, limited and predictable through pattern recognition

Pattern recognition technology made possible by analysis of thousands of GEM PAKs in clinical use, enables detection and correction of common errors

Continuous monitoring of all analytical processes before and after every sample for ultimate assurance

Menü- und PAK-Konfigurationen

FLEXIBLE GEM PAK CUSTOMIZATION


  • Gemessene Parameter
    pH, pCO2, pO2, Na+, K+, Ca++, Cl, Glu, Lac, Hct, tHb, O2Hb, COHb, MetHb, HHb, tBili, sO2

    Berechnete Parameter
    BE(B), BE(ecf), tHb(c), Ca++ (7,4), Anionenlücke, P/F Ratio, pAO2, CaO2, CvO2, p50, O2cap, sO2(c), sO2, HCO3 – std, HCO3 – (c), A-aDO2, paO2/pAO2, RI, CcO2, a-vDO2, Qsp/Qt (est), Qsp/Qt, Hct(c)

    ꭞ sO2 = O2Hb/O2Hb+HHb

  • Testzahl

    75, 150, 300, 450, 600*

    Menükonfigurationen

    Blutgase, Hct, tHb, O2Hb, HHb, COHb, MetHb, sO2, tBili**

    Blutgase, Elektrolyte, Hct, tHb, O2Hb, HHb, COHb, MetHb, sO2, tBili**

    Blutgase, Elektrolyte, Glu, Lac, Hct, tHb, O2Hb, HHb, COHb, MetHb, sO2, tBili**

     

    * 30 Tage Haltbarkeit der Kassetten im Gerät. Bei Kassetten für 600 Tests: 21 Tage
    **GEM Premier Kassetten sind mit oder ohne tBili erhältlich.

Dateien & Ressourcen


Name
Herunterladen
CE GEM 4000
CE Kassetten GEM 3000/3500/4000

Ergänzende Produkte


Name
Package size
Part number
Herunterladen

CVP 1 mit CO-Oxymetrie

10 x 1,8
00025000115

CVP 2 mit CO-Oxymetrie, Bilirubin

10 x 1,8
00025000125

CVP 3 Hämatokrit

10 x 1,8
00025000130

CVP 4 Hämatokrit

10 x 1,8
00025000140

CVP 5 Bilirubin

10 x 1,8
00025000145

GEM Premier 4000 Kassette (21 Tage)

1 x 600
00027360004

GEM Premier 4000 Kassette (21 Tage)

1 x 600
00027360005

GEM Premier 4000 Kassette (30 Tage)

1 x 75
00027407505

GEM Premier 4000 Kassette (30 Tage)

1 x 150
00027415005

GEM Premier 4000 Kassette (30 Tage)

1 x 300
00027430005

GEM Premier 4000 Kassette (30 Tage)

1 x 450
00027445005

GEM Premier 4000 Kassette (30 Tage)

1 x 75
00027407509

GEM Premier 4000 Kassette (30 Tage)

1 x 150
00027415009

GEM Premier 4000 Kassette (30 Tage)

1 x 300
00027430009

GEM Premier 4000 Kassette (30 Tage)

1 x 450
00027445009

GEM Premier 4000 Kassette (21 Tage)

1 x 600
00027360009

GEM Premier 4000 Kassette (30 Tage)

1 x 75
00027407511

GEM Premier 4000 Kassette (30 Tage)

1 x 150
00027415011

GEM Premier 4000 Kassette (30 Tage)

1 x 300
00027430011

GEM Premier 4000 Kassette (30 Tage)

1 x 450
00027445011

GEM Premier 4000 Kassette (21 Tage)

1 x 600
00027360011

GEM Premier 4000 Kassette (30 Tage)

1 x 75
00027407504

GEM Premier 4000 Kassette (30 Tage)

1 x 150
00027415004

GEM Premier 4000 Kassette (30 Tage)

1 x 300
00027430004

GEM Premier 4000 Kassette (30 Tage)

1 x 450
00027445004

GEM Premier 4000 Kassette (30 Tage)

1 x 75
00027407508

GEM Premier 4000 Kassette (30 Tage)

1 x 150
00027415008

GEM Premier 4000 Kassette (30 Tage)

1 x 300
00027430008

GEM Premier 4000 Kassette (30 Tage)

1 x 450
00027445008

GEM Premier 4000 Kassette (21 Tage)

1 x 600
00027360008

GEM Premier 4000 Kassette (30 Tage)

1 x 75
00027407510

GEM Premier 4000 Kassette (30 Tage)

1 x 150
00027415010

GEM Premier 4000 Kassette (30 Tage)

1 x 300
00027430010

GEM Premier 4000 Kassette (30 Tage)

1 x 450
00027445010

GEM Premier 4000 Kassette (21 Tage)

1 x 600
00027360010

CVP 1 mit CO-Oxymetrie

10 x 1,8
00025000115

CVP 2 mit CO-Oxymetrie, Bilirubin

10 x 1,8
00025000125

CVP 3 Hämatokrit

10 x 1,8
00025000130

CVP 4 Hämatokrit

10 x 1,8
00025000140

Verwandte Produkte


Kontakt

Kontaktieren Sie uns direkt, indem Sie das nebenstehende Formular ausfüllen.

Tel: +43 1 256 58 00-22

DATENSCHUTZRICHTLINIE:

Werfen GmbH verarbeitet Ihre personenbezogenen Daten, um auf Ihre Informations- oder Unterstützungsanfragen zu reagieren oder um Ihre Bedürfnisse zu verstehen und Ihnen einen besseren Service bieten zu können, wobei wir uns auf unser berechtigtes Interesse berufen. Weitere Informationen über unsere Datenschutzpraktiken und wie Sie Ihre Rechte ausüben können, finden Sie in unserer Datenschutzerklärung. Sie können uns auch unter kontact-dsb@althammer-kill.de. kontaktieren.